You Searched For: Complete HPLC Systems

Sophisticated complete HPLC systems offer an easy and improved liquid chromatography method for separating mixture compounds essential for further quantification or identification analyses. Instead of the sample traveling through the column by gravitational means, this equipment utilizes a forced air pressure push to achieve faster results. Pumps maintain a consistent flow rate while ultra-sensitive detectors assist with accurate retention times. For better separations, the complete HPLC systems allow pre-packed stationary phase materials with smaller particle sizes.

Sophisticated complete HPLC systems offer an easy and improved liquid chromatography method for separating mixture compounds essential for further quantification or identification analyses. Instead of the sample traveling through the column by gravitational means, this equipment utilizes a forced air pressure push to achieve faster results. Pumps maintain a consistent flow rate while ultra-sensitive detectors assist with accurate retention times. For better separations, the complete HPLC systems allow pre-packed stationary phase materials with smaller particle sizes.


31  results were found

Sort Results

List View Easy View (new)
SearchResultCount:"31"
Description: Chromaster Plus HPLC CM6310 - column oven for max. 6×150 mm columns or max. 3×300 mm columns, Temperature range 4 to 90 °C with fast heating and cooling block. 1 µl preheater. Optional switching valves available. Column management system option available
Catalog Number: 903-0361
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5310 Advanced Spec -column oven with 0,5 m e-Line cable, power cable and integrated 600 bar VICI switching valve
Catalog Number: 903-0367
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster HPLC 5450 refractive index detector, With short stabilisation time and flow cell with variable temperature setting. Refractive index range: 1 - 1,75
Catalog Number: 903-0528
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5280 autosampler with Peltier cooling unit and 100 µl syringe. 600 bar max. operating pressure, ≤0,003% RSD specified carry over. Direct injection with needle integrated into sample loop for low sample volumes. Temperature setting range: 4 to 35 °C. Wash solvent delivery by syringe. 200 x 1,5 ml vial rack included. Other rack options available
Catalog Number: 903-0345
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5280 autosampler with 100 µl syringe. 600 bar max. operating pressure, ≤0,003% RSD specified carry over. Direct injection with needle integrated into sample loop for low sample volumes. Wash solvent delivery by syringe. 200 x 1,5 ml vial rack included. Other rack options available
Catalog Number: 903-0344
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5280 thermostat direct injection autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5280 autosampler with 200 vial peltier rack, 4 to 35 °C, and direct injection with needle integrated into sample loop, 100 µl syringe for accurate sample metering. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. All cables and interface board included
Catalog Number: 903-0358
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC complete 600 bar system for standard bore columns with CM5160 manual purge quaternary gradient pump, CM5260 thermostat standard loop autosampler, CM5310 column oven, CM5430 diode array detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial peltier thermostatted rack from 1 to 45 °C and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. 5430 diode array detector with 1.024 bit PDA, auto wavelength check, range 190 - 900 mm with 13 µl, 10 mm cell. All cables and interface board included
Catalog Number: 903-0355
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus Basic UV CSA5HE package including CM5160 pump with manual purge valve, 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, CM5260 autosampler, CM5310 column oven, CM5410 UV detector, organiser, interface control board, ChromSwordAuto® 5 Hitachi Edition including CDS and Scout System, VWR®/Hitachi starter kit
Catalog Number: 903-0370
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5260 thermostat standard loop autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial peltier thermostatted rack from 1 to 45 °C and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. All cables and interface board included
Catalog Number: 903-0342
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC complete 600 bar system with CM5160 manual purge quaternary gradient pump, CM5260 standard loop autosampler, CM5310 column oven and CM5410 variable wavelength UV detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial rack and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. 5410 variable wavelength UV detector with 13 µl, 10 mm flow cell, double beam ratio photometric system with Hg lamp for checking wavelength. Wavelength range: 190 - 600 nm. Chromaster System Manager control and data acquisition software included. All cables and interface board included
Catalog Number: 903-0337
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5280 direct injection autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5280 autosampler with 200 vial rack and direct injection with needle integrated into sample loop, 100 µl syringe for accurate sample metering. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. All cables and interface board included
Catalog Number: 903-0359
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus Standard DAD CSA5HE package including CM5160 pump with manual purge valve. 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, user interface key pad, CM5260 autosampler with thermostat, 5310 column oven, 3-column selection Rheodyne® valve, CM5430 DAD without flow cell, standard flow cell, organiser, Interface Control Board, ChromSwordAuto® 5 Hitachi Edition including CDS and Scout System, VWR®/Hitachi starter kit
Catalog Number: 903-0371
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC complete 600 bar system with CM5160 auto purge quaternary gradient pump, CM5260 standard loop autosampler, CM5310 column oven and CM5420 variable wavelength UV-VIS detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial rack and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. 5410 variable wavelength UV detector with 13 µl, 10 mm flow cell, double beam ratio photometric system with Hg lamp for checking wavelength. Wavelength range: 190 - 600 nm. Chromaster System Manager control and data acquisition software included. All cables and interface board included
Catalog Number: 903-0396
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5260 standard loop autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial rack and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. All cables and interface board included
Catalog Number: 903-0343
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus Professional DAD CSA5HE package including CM5160 pump with auto-purge valve. 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, user interface key pad, plunger wash pump, CM5260 autosampler with thermostat, CM6310 column oven, 6 column selector Rheodyne® valve, CM5430 DAD without flow cell, standard flow cell, organiser, interface control board
Catalog Number: 903-0372
UOM: 1 * 1 items
Supplier: VWR Collection


17 - 31 of 31