You Searched For: Biochemistry Learning Activities

Electroporation electrodes are for use in the electroporation (opening pores in cell membranes with a pulse of electricity to introduce DNA in bacteria or other cells) of adherent cells in vivo or in utero. These electrodes can be used for a variety of applications, including in utero transfection, transdermal drug delivery, and electroporation therapy. Electrode assemblies are designed to produce homogeneous fields of electricity, and they are easy to clean and sterilize.

Electroporation electrodes are for use in the electroporation (opening pores in cell membranes with a pulse of electricity to introduce DNA in bacteria or other cells) of adherent cells in vivo or in utero. These electrodes can be used for a variety of applications, including in utero transfection, transdermal drug delivery, and electroporation therapy. Electrode assemblies are designed to produce homogeneous fields of electricity, and they are easy to clean and sterilize.


18  results were found

Sort Results

List View Easy View (new)
SearchResultCount:"18"
Description: The Petri Pulser™ electrode is a reusable electroporation applicator designed to fit into each single well of a 6-well plate or an individual 35 mm diameter Petri dish. It is suitable for the electroporation of adherent cells in situ or as an alternative to cuvette electroporation for larger cell suspensions volumes.
Catalog Number: 732-0025
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: These reusable oocyte Petri electrodes are ideal for electroporation of oocytes, embryos, or other cell types in small volumes.
Catalog Number: BTXI45-2059
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: 2-Needle Array™ electrodes are needle-style electrodes specifically designed for <i>in vivo</i> drug or gene delivery applications. The electrode consists of a reusable 2-Needle Array™ handle and sterile, disposable, 2-needle arrays.
Catalog Number: 732-0030
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: This petri dish electrode is designed to be used with a 100 mm petri dish that functions as the electroporation chamber. The electrode is used to electroporate adherent cells or tissue grown in a petri dish.
Catalog Number: 732-0000
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: Genepaddles are non invasive, paddle-style, reusable electrodes designed for <i>in vivo</i> and <i>in vitro</i> applications, such as gene delivery (IVEGD) in mouse embryos. The electrodes are placed anterior and posterior to the embryo following injection of the molecule of interest, and an electroporation pulse is delivered.
Catalog Number: 732-0032
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: This tissue chamber is specifically designed to handle ex-vivo tissue samples that are either larger than normal or have a unique shape making it difficult to transfect using other standard electrodes. This is an efficient method to deliver genes and drugs to a wide range of tissue types including cornea, muscle and skin.
Catalog Number: BTXI45-0505
UOM: 1 * 1 KIT
Supplier: Harvard Apparatus


Description: Calliper electrodes are reusable, calliper-style electrodes for a variety of <i>in vivo</i> applications such as drug or gene delivery. Calliper electrodes consists of a calliper and a pair of plate electrodes.
Catalog Number: 732-0002
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: This flat electrode can be used for both electroporation and electro cell fusion. It generates either a divergent or homogeneous field depending on the orientation of the grooved electrodes.
Catalog Number: 700-4812
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: Tweezertrodes™ are reusable, tweezer style electrodes for<i> in vivo</i> drug or gene delivery applications.
Catalog Number: 732-0015
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: Reusable plate electrode designed to directly electroporate adherent cells or electroporate cultured cell monolayers on filters. The Adherent Cell electrode is a reusable electroporation applicator designed to fit into each single well of a 24-well or 12-well plate.
Catalog Number: BTXI45-0531
UOM: 1 * 1 KIT
Supplier: Harvard Apparatus


Description: The BTX Meander Fusion Chamber is a novel microslide design which is specifically used for electro cell fusion. The chamber generates a divergent field and is used for fusion of mammalian cells, plant, yeast, fungi and microorganisms.
Catalog Number: 700-4804
UOM: 1 * 4 items
Supplier: Harvard Apparatus


Description: This electrode is designed for delicate and/or difficult tissue transfection. Ex vivo electropoartion is an efficient, effective method to introduce genes, drugs or any number of molecules into a tissue. Sandwich configuration ensures a homogeneous field of energy for optimum transfection.
Catalog Number: BTXI45-0490
UOM: 1 * 1 KIT
Supplier: Harvard Apparatus


Description: Genetrodes™ are paired, reusable, needle style electrodes that are ideal for <i>in vivo</i> and <i>in ovo</i> electroporation applications, including drug and gene delivery.
Catalog Number: 732-0014
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: AgilePulse™ needle array electrodes are miniature needles designed to provide superior, highly uniform electric fields in dermal or muscular tissue as part of the AgilePulse™<i> in vivo</i> ID (intra dermal) or IM (intra muscular) gene delivery electroporation system.
Catalog Number: 731-0329
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: These in vivo style electrode specifically designed for muscle gene delivery. Among the non-viral techniques for in vivo gene transfer, the direct injection of plasmid DNA into muscle is simple, inexpensive and safe. The electrode is available in two gap sizes, 5 mm and 10 mm.
Catalog Number: 732-0861
UOM: 1 * 1 items
Supplier: Harvard Apparatus


Description: Microslides have been used for embryo manipulation and cell or protoplast fusion. The Microslide fits on the microscope allowing observation of the alignment and fusion process.
Catalog Number: 732-0006
UOM: 1 * 1 items
Supplier: Harvard Apparatus


1 - 16 of 18