You Searched For: pH and Multi-Parameter Meters

These rugged pH and multi-parameter meters accurately provide the quick water quality measurements essential for electrochemistry research. Choose from compact benchtop or portable pen-styles to fit laboratory or field environments. Efficient dual or multi-parameter technology simultaneously determines different substance levels. The simple user interface shows prompted instructions on high resolution displays. Store the calibrations of potential hydrogen or oxidation reduction with memory storage capability. Incorporating waterproof construction, pH and multi-parameter meters endure harsh environs.

These rugged pH and multi-parameter meters accurately provide the quick water quality measurements essential for electrochemistry research. Choose from compact benchtop or portable pen-styles to fit laboratory or field environments. Efficient dual or multi-parameter technology simultaneously determines different substance levels. The simple user interface shows prompted instructions on high resolution displays. Store the calibrations of potential hydrogen or oxidation reduction with memory storage capability. Incorporating waterproof construction, pH and multi-parameter meters endure harsh environs.


388  results were found

Sort Results

List View Easy View (new)
SearchResultCount:"388"
Description: pH meter, pH 3110 set SenTix® 41 (instrument in field case with SenTix® 41 pH electrode, STP4 and STP7 buffers, stand, beaker, instruction manual, CD-ROM and batteries), pH 3110 Set (incl. Sentix® 41 pH sensor), Handheld, Set with electrodes, mV: ±2000, Temperature: −5...+105 °C, DIN / 4 mm banana, Datalogging: No, Outputs: -, 4× 1,5 V AA or 4× 1,2 V NiMH, Weight: 0,6 kg, IP 66/67
Catalog Number: 662-0505
UOM: 1 * 1 items
Supplier: WTW


Description: pH meter, pH 3310 (instrument only with instruction manual, CD-ROM, batteries, software and USB cable), pH 3310 (without sensor), Handheld, Meter only; without electrodes, mV: ±2500, Temperature: −5...+105 °C, DIN / 4 mm banana, Datalogging: Yes, 200, Outputs: USB, 4× 1,5 V AA or 4× 1,2 V NiMH, Weight: 0,6 kg, IP 66/67, GLP
Catalog Number: 662-0999
UOM: 1 * 1 items
Supplier: WTW


Description: pH Meter, pH tester, Checker, with screw-type, epoxy-body electrode, Checker, Tester, Set with electrodes, 2× 1,4 V batteries, Weight: 0,063 kg
Catalog Number: 39771.KT
UOM: 1 * 1 items
Supplier: Alfa Aesar

MSDS


Description: pH/mV/ion meter, VWR® pHenomenal®, Bench pH/mV/°C/ion meter pHenomenal® IS 2100L, IS 2100L, Bench, Set with electrodes, mV: ±1200 / ±2500, Temperature: −5...+105 °C, ISE: 0,001 - 9999 mg/l; 10⁻⁹ - 99,999 mol/l; 0,001 - 99999 ppm, BNC for pH/banana for temperature, Datalogging: Yes, 5000, Outputs: USB connection (slave, bidirectional), Mains or 4× AA batteries, IP 43/GLP
Catalog Number: 662-1658
UOM: 1 * 1 SET
Supplier: VWR Collection


Description: pH Meter, VWR®, pH/mV/°C meter, lab use, Bench, Set with electrodes, mV: –2,000 …+2000,0 mV, Temperature: –50,0 …+200,0 °C, BNC for pH/mV, RCA (CINCH) for temperature, Yes, Outputs: USB
Catalog Number: 662-2380
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (2 measurement inputs), Multi 3620 IDS, set C with SenTix® 940 pH electrode, TetraCon® 925 conductivity cell, case and armoring SM Pro, Multi 3620 IDS, set C with SenTix® 940 pH electrode and TetraCon® 925 conductivity cell, Handheld, Set with electrodes, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2140
UOM: 1 * 1 items
Supplier: WTW


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (3 measurement inputs), Multi 3630 IDS, single meter only in a case, Multi 3630 IDS, single meter only in a case, Handheld, Meter only; without electrodes, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2143
UOM: 1 * 1 items
Supplier: WTW


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (2 measurement inputs), Multi 3620 IDS, single meter only in a case, Multi 3620 IDS, Handheld, Meter only; without electrodes, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2051
UOM: 1 * 1 items
Supplier: WTW


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (3 measurement inputs), Multi 3630 IDS, set F with SenTix® 940 pH electrode, TetraCon® 925 conductivity cell, FDO® 925 optical DO sensor, case and armoring SM Pro, Multi 3630 IDS, set F with SenTix® 940 pH electrode, TetraCon® 925 conductivity cell and FDO® 925 optical DO sensor, Handheld, Set with electrodes, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2144
UOM: 1 * 1 items
Supplier: WTW


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (3 measurement inputs), Multi 3630 IDS, set without sensor, including case, QSC-Kit, accessories and armoring SM Pro, Multi 3630 IDS, set without sensor, including field case, accessories and armor SM Pro, Handheld, Meter only; without electrodes, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2146
UOM: 1 * 1 items
Supplier: WTW


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (2 measurement inputs), Multi 3620 IDS, set G with SenTix® 940-3 pH electrode, TetraCon® 925-3 conductivity cell, FDO® 925-3 optical DO sensor, case and armoring SM Pro, Multi 3620 IDS, set G with SenTix® 940-3 pH electrode, TetraCon® 925-3 conductivity cell and FDO® 925-3 optical DO sensor, Handheld, Set with electrodes, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2141
UOM: 1 * 1 items
Supplier: WTW


Description: Multi-parameter meter, MultiLine®, Multi-parameter meter (3 measurement inputs), Multi 3630 IDS, set G with SenTix® 940-3 pH electrode, TetraCon® 925-3 conductivity cell, FDO® 925-3 optical DO sensor, case and armoring SM Pro, Handheld, Datalogging: Yes, 500/10000, Outputs: Mini-USB-B, USB-A, Charger (100 - 240 V, 50 - 60 Hz), 4×1,2 V NiMH batteries (type AA), or via Mini USB-B, W×D×H: 180×80×55 mm, Weight: 0,4 kg, IP 67
Catalog Number: 662-2145
UOM: 1 * 1 items
Supplier: WTW


Description: pH/mV/°C/ion meter, inoLab®, inolab pH/ION 7320 meter only (BNC connection) without integral printer or electrode, 7320 (BNC), Bench, Meter only; without electrodes, mV: ±1200 / ±2500, Temperature: −5...+105 °C, ISE: 0 - 2000 mg/l, DIN or BNC, Datalogging: Yes, 500, Outputs: USB, IP 43, GLP
Catalog Number: 662-1685
UOM: 1 * 1 items
Supplier: WTW


Description: pH/mV/°C/ion meter, inoLab®, inolab pH/ION 7320 meter only (DIN connection) with integral printer but without electrode, 7320, with printer, Bench, Meter only; without electrodes, mV: ±1200 / ±2500, Temperature: −5...+105 °C, ISE: 0 - 2000 mg/l, DIN or BNC, Datalogging: Yes, 500, Outputs: USB, IP 43, GLP
Catalog Number: 662-1684
UOM: 1 * 1 items
Supplier: WTW


Description: pH/mV/°C/ion meter, inoLab®, inolab pH/ION 7320 meter only (DIN connection) without integral printer or electrode, 7320 (DIN), Bench, Meter only; without electrodes, mV: ±1200 / ±2500, Temperature: −5...+105 °C, ISE: 0 - 2000 mg/l, DIN or BNC, Datalogging: Yes, 500, Outputs: USB, IP 43, GLP
Catalog Number: 662-1683
UOM: 1 * 1 items
Supplier: WTW


Description: pH/mV/°C/ion meter, inoLab®, inolab pH/ION 7320 meter only (BNC connection) with integral printer but without electrode, 7320, with printer, Bench, Meter only; without electrodes, mV: ±1200 / ±2500, Temperature: −5...+105 °C, ISE: 0 - 2000 mg/l, DIN or BNC, Datalogging: Yes, 500, Outputs: USB, IP 43, GLP
Catalog Number: 662-1686
UOM: 1 * 1 items
Supplier: WTW


33 - 48 of 388